MEDICAL TECHNOLOGY · HUMAN CARE
GUBBINI MIDI 18.5 Fr. sheaths and components from the TONTARRA catalogue
TONTARRA

TONTARRA GUBBINI MIDI 18.5 Fr. Hystero-Resectoscope

Model GUBBINI MIDI 18.5 Fr.

TONTARRA GUBBINI MIDI system with 18.5 Fr. outer and 17.5 Fr. inner sheaths, rotatable and non-rotatable configurations, a 5 Fr. instrument channel and Ø 2.9 mm optics. The MIDI resectoscopy electrode table lists reusable bipolar and single-use SALINÆ options.

Compare all three GUBBINI models →
PRODUCT HIGHLIGHTS

Product highlights

01

18.5 Fr. MIDI configuration

Larger sheath size than Original and Ellipse. The manufacturer describes loops for more extensive intrauterine lesions, subject to clinical assessment.

02

See & Treat configuration

Exchange the inner and working sheaths while retaining the outer sheath, supporting hysteroscopy and resectoscopy in one system.

03

Continuous flow and Quick Lock

Sheaths provide inflow and outflow with Quick Lock connections for assembly and component exchange.

04

2.9 mm optics and 5 Fr. instrumentation

Select the telescope angle for the model and procedure. The working sheath accepts micro instruments and hysteroscopy electrodes through its instrument channel.

05

Dedicated MIDI bipolar electrodes

Reusable 30° angled loop, straight loop, knife, Ø 2 mm ball and Ø 2 mm roller. SALINÆ versions cover four forms in the table.

TECHNICAL SPECIFICATIONS

Technical specifications

Product specifications and values
SpecificationDetails / value and unit
Outer / inner sheath size18.5 Fr. / 17.5 Fr.
Rotatable sheath configurationOuter 582-180-24; inner 582-180-26; green coding
Working sheath for rotatable configuration582-180-39; 5 Fr. instrument channel
Non-rotatable sheath configurationOuter 582-180-22; inner 582-180-21; green/blue outer sheath coding
Working sheath for non-rotatable configuration582-180-38; for 582-180-22; 5 Fr. instrument channel
MIDI working element582-180-00B; passive cutting, closed handle, titanium hinge, Quick Lock
Telescope size and anglesØ 2.9 mm; 0°, 12°, 30°. Most electrodes recommend 12°/30°; straight loop recommends 0° in the page 33 table.
30° angled loopBipolar 582-180-40B; SALINÆ 582-180-40B-S
Straight loopBipolar 582-180-41B; SALINÆ 582-180-41B-S
Knife electrodeBipolar 582-180-42B; SALINÆ 582-180-42B-S
Ø 2 mm ball electrodeBipolar 582-180-43B; SALINÆ 582-180-43B-S
Ø 2 mm roller electrodeBipolar 582-180-44B; no SALINÆ code listed
Resectoscopy electrode modeMIDI electrode table lists bipolar only; NaCl 0.9% distension medium
SALINÆ packagingSterile, individually packaged, single-use; 5 per unit
Safety distance holder582-150-02GUB; 1.1 mm; optional, confirm current pack quantity
EQUIPMENT & ACCESSORIES

Equipment & accessories

  • HD+2 telescopes

    Ø 2.9 mm, FL 300 mm, 80° field of view: 0° 601-103-00HD2; 12° 601-103-12HD2; 30° 601-103-30HD2. Listed as autoclavable.

  • Micro instruments for the 5 Fr. channel

    Ø 1.6 mm, length 340 mm. LL versions have Luer Lock; FS versions have proximal anti-kink protection without Luer Lock. Forceps, scissors and punch codes appear below.

  • Hysteroscopy electrodes

    5 Fr.: monopolar flexible, 470 mm: button 582-510-05, angled needle 582-511-05, loop 582-514-05. Bipolar semi-rigid, 360 mm: button 582-515-05, angled needle 582-516-05, straight needle 582-517-05.

  • HF cables and generators

    Select the cable for the procedure, connectors and generator model. The catalogue lists PULSAR MB350, PULO/MB350. Generator and cables are configuration options, not an assumed standard package.

  • Instrument basket

    582-150-60GU perforated sheet basket with instrument and telescope holders; 480 × 245 × 80 mm.

ADDITIONAL INFORMATION

Additional information

Catalogue application scope

The manufacturer describes diagnostic and operative hysteroscopy applications including polypectomy, myomectomy, biopsy and intrauterine pathology. Patient selection, procedure and analgesia depend on the clinician and applicable IFU.

Configuration and compatibility

Confirm sheath type, telescope angle, electrode, working element, cable and generator as a matched configuration. Images illustrate configurations; price and included items must be confirmed in the quotation.

Reprocessing and instructions

The catalogue lists HD+2 telescopes as autoclavable. Use each component’s IFU for cleaning and sterilization cycles. Catalogue information does not replace instructions; single-use SALINÆ electrodes must not be reused.

Edition differences

Compiled from model-specific tables in catalogue 999-351-03E and cross-checked with flyer 999-356-02E. Some codes, cable lengths and generator listings differ. Page 39 lists Emed at 4.0 m and Bowa at 4.5 m, while model tables list 3.0 m. Confirm current manufacturer specifications for the offered configuration.

Differences from Original and Ellipse

MIDI uses working element 582-180-00B and the 582-180 electrode family; do not substitute Original/Ellipse electrode codes. The catalogue describes cervical dilation and anesthesia for 18.5 Fr.; the clinician determines the appropriate approach.

Electrode and code discrepancies

Although overview text calls the system hybrid, pages 28 and 33 list MIDI resectoscopy electrodes as bipolar only. This page uses working element 582-180-00B and sheath codes from model-specific pages 27–28 because parts of the page 34 summary differ.

Sources and related models

Catalogue 999-351-03E, pp. 8–11, 26–28, 30–35 and 38–40. Compare with Original 16 Fr. and Ellipse 14.9 Fr. The two smaller-system flyers are not used as evidence for MIDI specifications.

Further details

Micro instruments: ordering codes

  • Oval double-action biopsy forceps: 583-214-16LL
  • Blunt single-action scissors: 583-228-16LL / 583-228-16FS
  • Pointed single-action scissors: 583-229-16LL / 583-229-16FS
  • Oval biopsy and grasping forceps: 583-256-16LL / 583-256-16FS
  • Through-cutting punch: 583-258-16LL
  • Oval double-action tenaculum forceps: 583-278-16LL
  • Myoma fixation instrument: 583-280-00

Bipolar resectoscopy cables

  • Erbe ICC/ACC, Storz: 287-200-30BR
  • Berchthold / Martin Maxium: 287-205-30BR
  • PULSAR MB350 / international 2-pin: 287-215-30BR
  • Erbe VIO 300D / VIO3 and Karl Storz Autocon II 400: 287-220-30BR
  • Emed Spectrum: 287-225-30BR
  • Bowa ARC 350 / 400: 287-230-30BR

The tables on pages 18/23/28 list 3.0 m for this group. Confirm the offered cable length and connectors before ordering.

Hysteroscopy electrode cables

  • Bipolar 3.0 / 5.0 m: Erbe ICC/ACC/Storz 287-200-30 / 287-200-50; Berchthold/Martin 287-205-30 / 287-205-50; US 2-pin banana 287-210-30 / 287-210-50; Valleylab/international 2-pin 287-215-30 / 287-215-50
  • Monopolar 3.0 m: Aesculap/Rudolf/Martin/Berchthold GN Ø 4 mm 582-530-01; Erbe/ICC/ACC/Storz Ø 5 mm 582-531-02; Valleylab/Conmed Ø 8 mm 582-532-03; banana Ø 4 mm 582-533-04

BR resectoscopy cables and hysteroscopy electrode cables are separate groups and must be matched to the instrument.

Light system and further accessories

  • Ø 3.5 mm fiber light guides, 1800 / 2300 / 3000 / 5000 mm: Standard 540-803-18 / 23 / 30 / 50; HTT 540-813-18 / 23 / 30 / 50. Specify the complete article number and separate connectors.
  • Projector-side connectors: Storz/Aesculap 540-890-02; Olympus/ACMI 540-890-10; Olympus new 540-890-14; Wolf 540-890-04; ACMI/British/Codman 540-890-01
  • Telescope-side connectors: TONTARRA/Storz/Aesculap/Olympus old 540-880-02; Olympus new 540-880-04; Wolf/HSW/Dyonics snap 540-880-13 or clip 540-880-05; ACMI/British/Codman 540-880-01
  • HYSTEROBLOCK needle Belo/2-PB02N, 20G, 270 mm, 10 per unit, is an optional catalogue accessory manufactured by BEL Bio Engineering Laboratories S.R.L.

These are catalogue options; they do not imply that all items are included in a procurement package.

คำถามที่พบบ่อย / FAQ

Are monopolar MIDI resectoscopy electrodes listed?

The supplied model-specific and electrode tables list bipolar MIDI electrodes only. Although the overview says hybrid, an unlisted monopolar option is not confirmed.

Do both sheath configurations use the same working sheath?

No. The rotatable configuration uses 582-180-39; the non-rotatable 582-180-22 outer sheath uses 582-180-38.

Is a single-use roller listed?

The table lists reusable roller 582-180-44B and no SALINÆ roller code.

Are optics and accessories included?

Items on this page are catalogue configuration options. Confirm components and quantities in the quotation.

Find the right solution for your organization

Contact our team to confirm models, specifications, equipment and supply terms.

Talk to our team ↗
โทร / CallLINE @tawanmcweis
REQUEST FOR QUOTATION

Your quotation list

Add equipment, set quantities and send your requirements through our contact form. This list is not an order.

Continue to request →