MEDICAL TECHNOLOGY · HUMAN CARE
Navigator 2.0 control unit and gamma probe; example configuration
Dilon Technologies
Radioguided surgery

Navigator™ 2.0 System | Surgical Gamma Probe System

Model Navigator™ 2.0 System

Dilon Navigator™ 2.0 is a battery-powered surgical gamma detection system for radio-guided procedures, including lymphatic mapping. Visual counts and audible feedback assist localization, with wireless or cabled probes selected for the application.

System
Navigator™ 2.0
Operation
Non-imaging gamma detection and quantification
Control-unit power
Replaceable rechargeable battery
PRODUCT UNDERSTANDING

Principles & terminology

Radioguided surgery

A gamma-probe system detects radiation signals for radioguided surgery using a probe and control unit. Probe selection must match the radionuclide and system requirements.

Product information & documentation ↗

Terms used in the specifications

Gamma probe
The gamma-radiation detector used with its control unit.
Radioguidance
Use of detected radiation signals to support localisation during a procedure.
DEVICE FEATURES

Key device features

01

Counts and audible feedback

Track gamma activity using displayed counts and audible feedback during the indicated procedure.

02

Battery-powered placement

The control unit operates without a mains lead during use. A new fully charged battery provides approximately 10–12 hours nominal continuous operation.

03

Application-specific probes

Wireless and cabled configurations are available. The Wireless Pilot Probe is restricted to Tc-99m.

04

Reusable surgical probes

Clean and sterilize reusable probes using the validated method and cycle for the exact probe model.

05

Compact control unit

The control unit with battery weighs 2.0 kg and measures 20 × 24 × 12 cm for operating-room placement planning.

TECHNICAL SPECIFICATIONS

Technical specifications

Product specifications and values
SpecificationDetails / value and unit
SystemNavigator™ 2.0
OperationNon-imaging gamma detection and quantification
Control-unit powerReplaceable rechargeable battery
Nominal battery runtimeApproximately 10–12 hours; new fully charged battery
Weight with battery2.0 kg
Dimensions W×H×D20 × 24 × 12 cm
FeedbackVisual counts and audible feedback
Wireless probe isotopeTc-99m only
ReferenceN2-5000-07-001 Rev 21 / 24 MAR 2025
EQUIPMENT & ACCESSORIES

Equipment & accessories

  • Core system configuration

    Reference system N2-9800-00 includes a two-bay charger and two control-unit batteries. Confirm the quoted supplied configuration.

  • Selected probe and accessories

    Specify the appropriate probe, any required cabled-probe lead and sterilization tray separately in the quotation.

ADDITIONAL INFORMATION

Additional information

Radio-guided localization

The system detects gamma emissions in tissue for indicated radio-guided procedures. Use it within the trained clinical team’s radiopharmaceutical workflow. It reports counts and sound; it does not create images or deliver therapeutic radiation.

Match the probe and isotope

Wireless operation uses Tc-99m. I-125, In-111 and 511 keV applications require compatible cabled probes and the appropriate connection cable; control-unit settings do not establish universal probe compatibility.

Plan OR and sterile-processing support

Treat the control unit, probes and cables as separate reprocessing components. Use only the validated method for the exact item; do not assume steam-autoclave compatibility. Confirm the department’s sterilizer and cycle before procurement.

Further details & references

References

Product: https://dilon.com/navigator-system/

Probe sterilization: https://dilon.com/navigator-sterilization/

Navigator 2.0 User Manual and Service Guide, N2-5000-07-001 Rev 21 (24 March 2025). Checked 10 November 2026; verify the supplied model and applicable instructions.

คำถามที่พบบ่อย / FAQ

What is Navigator 2.0 used for?

It detects and quantifies gamma activity for indicated radio-guided procedures, including lymphatic mapping, under trained professional use.

Can wireless probes be used with every isotope?

No. Wireless Pilot Probes use Tc-99m only. I-125, In-111 and 511 keV require compatible cabled probes.

How long does the control-unit battery last?

Approximately 10–12 hours nominal continuous use with a new fully charged battery. Actual duration depends on battery condition and use.

Can every component be steam sterilized?

Use the validated method for the exact probe. Do not assume autoclave compatibility or apply probe reprocessing to the control unit.

What information should I provide for a quotation?

Provide the procedure, isotope, probe requirement, sterilizer and quantity so the probe, charger, cables and supplied contents can be confirmed.

Discuss technical specifications and system configuration

Contact our team to confirm models, specifications, equipment and supply terms.

Talk to our team ↗
โทร / CallLINE @tawanmcweis
REQUEST FOR QUOTATION

Your quotation list

Add equipment, set quantities and send your requirements through our contact form. This list is not an order.

Continue to request →