Two selectable collection bottles
Two 3 L bottles and a changeover valve support organised collection. Monitor the level and switch bottles according to the manual; this is not two simultaneous suction channels.

Japanese TAF-W trolley medical suction unit with two selectable 3 L bottles. Explore vacuum, pump airflow, liquid protection and quotation options.
Two 3 L bottles and a changeover valve support organised collection. Monitor the level and switch bottles according to the manual; this is not two simultaneous suction channels.
The upper control area provides a vacuum regulator and gauge. Use the clinician-prescribed setting; −90 kPa describes maximum equipment performance.
The manual describes a float, level sensor and safety bottle. Correct assembly and inspection are required; these features do not replace level monitoring.
A wheeled unit with a handle can be assessed for bedside or procedure-area placement. Check clearance, mains access and cleaning workflows before selection.
| Specification | Details / value and unit |
|---|---|
| Configuration | Trolley; two 3,000 mL bottles selected by changeover valve, not simultaneous suction |
| Maximum equipment vacuum | −90 kPa ±10% |
| Pump discharge flow at 50 Hz | 78 L/min ±20% (pump only; not liquid aspiration rate) |
| Pump discharge flow at 60 Hz | 92 L/min ±20% (pump only) |
| Power supply in supplied manual | AC 220 V, 50–60 Hz |
| Current consumption | 50 Hz: 1.0 A ±10% | 60 Hz: 0.8 A ±10% |
| Dimensions W × D × H | Approx. 400 × 360 × 875 mm, excluding protrusions |
| Main unit weight | Approx. 21 kg, excluding aspirated liquid |
| Electrical classification | Class I | Type B applied part (suction tube) |
| Operating environment | +5 to +35°C | 30–75% RH, non-condensing |
| Storage environment | −10 to +60°C | 10–75% RH, non-condensing |
| Atmospheric pressure | 70–106 kPa |
| Current measurement conditions | 25 ±5°C | AC 220 V | −50 kPa |
| Manufacturer named in manual | KOUSHIN INDUSTRIES, INC., Japan | Sole distributor: SANKO MANUFACTURING CO., LTD. |
TAF-W main unit with two 3,000 mL bottle assemblies; verify the final supply list.
Dedicated power cord, two suction tubes, two catheter-holder sets and instruction manual.
Ask about compatible PTFE filter units, bottles, lids, seals, floats and tubing. Optional accessories are not automatically included.
The manual describes aspiration of blood, pus, exudate and washing liquid, as well as oral or airway secretions within the indicated use and professional supervision. Select patient-contact accessories for the procedure; equipment selection does not replace patient assessment.
Based on the supplied USER MANUAL TAF-W and supporting documents. Japanese domestic and other production variants may differ; verify the rating plate before ordering. Follow the manual for bottles, tubing, float and liquid protection. Internal servicing and electrical safety testing require trained personnel.
https://www.tawanmcweis.com/knowledge/how-to-choose-medical-suction-unit?lang=en
https://www.tawanmcweis.com/products/power-smile-s-ks-710?lang=en
No. A changeover valve selects one 3 L bottle at a time; the two bottles are not independent simultaneous suction channels.
No. It is the pump-only discharge airflow at 50 Hz under manufacturer conditions, not the actual liquid aspiration rate.
This is maximum equipment vacuum, not a patient setting. A healthcare professional must specify the setting for the patient, procedure and accessories.
The shared manual lists two 3 L bottles and approx. 21 kg for TAF-W, versus one 3 L bottle and approx. 20 kg for TAF-S. This page presents TAF-W; ask separately about the single-bottle model.
Contact our team to confirm models, specifications, equipment and supply terms.