MEDICAL TECHNOLOGY · HUMAN CARE
Plasma EDGE bipolar plasma resection system
Lamidey Noury
Electrosurgical systems

MCB Plasma EDGE Bipolar Plasma Resection System

Model Plasma EDGE

Plasma EDGE by Lamidey Noury is a bipolar plasma resection system for use in saline, combining an MCB generator, compatible working element and dedicated electrodes. The urology range includes 22 and 26 Fr. resectoscopes and electrode options for TURP, TURBT and PlasmaLEP. Gynaecology requires its own compatible scope and instrument configuration.

System
Bipolar plasma resection in saline
Urology resectoscope sizes
22 Fr. and 26 Fr., configuration dependent
22 Fr. sheath
22/19 Fr. double flow
PRODUCT UNDERSTANDING

Principles & terminology

Electrosurgical systems

An electrosurgical configuration includes the generator, instrument, electrodes, cables and associated components. Monopolar and bipolar systems have different circuit and accessory requirements.

Terms used in the specifications

Energy modality
The energy mode supported by the instrument and generator configuration.
Instrument compatibility
Reference-specific compatibility among instruments, cables and components.
DEVICE FEATURES

Key device features

01

Bipolar circuit at the electrode

The manufacturer places both bipolar poles and the attached cable at the electrode rather than using the sheath as the return path.

02

22 and 26 Fr. configurations

22 and 26 Fr. options are available. The 22 Fr. system uses a dedicated working element and a 2.9 mm / 30° optic.

03

Procedure-specific electrode options

Loop, needle, ball, vaporization and enucleation electrodes are available for procedure-specific configuration and compatibility review.

TECHNICAL SPECIFICATIONS

Technical specifications

Product specifications and values
SpecificationDetails / value and unit
SystemBipolar plasma resection in saline
Urology resectoscope sizes22 Fr. and 26 Fr., configuration dependent
22 Fr. sheath22/19 Fr. double flow
22 Fr. optic2.9 mm / 30° with a dedicated working element
Compatible working elementST / OL / WO-compatible options listed; verify exact optic, sheath and configuration
Thin loopVXRU1 — loop for TURBT; confirm current reference and configuration
Thick loopVXRU2 — TURP loop; gynaecology requires its own configuration
NeedleVXRUN — bladder-neck incision application subject to clinical selection
BallVXRUB — coagulation electrode
VaporizationVXRUV — select for the intended vaporization/coagulation use and applicable instructions
PlasmaLEP enucleationVXRUE — dedicated enucleation electrode
Additional electrode designsSlim Line 22 Fr. and Straight Bladder Loop; confirm references and compatibility
Electrode cableIntegrated cable attached to the electrode; check the delivered reference and single-use labelling
Saline temperature and plasma activationWarm saline is not required for plasma activation; this is not a patient irrigation-temperature prescription
UROLOGY APPLICATIONS

Configure for the intended procedures

BPH / TURP

For prostate resection, select a cutting loop and any coagulation or vaporization electrodes according to the surgeon’s plan. Coordinate hemostasis, visualization and irrigation.

TURBT

Select thin-loop or straight designs by tumour position, access and tissue-sampling needs. Depth control and obturator-reflex risk management remain clinical responsibilities.

BIPOLAR ENUCLEATION

PlasmaLEP · Mechanical separation supported by bipolar energy

PlasmaLEP combines a mechanically pushed wire structure with energy for cutting and coagulation during adenoma separation. Side insulation defines the active region. It is a bipolar enucleation technique requiring specific training.

PlasmaLEP electrode: design and active-region illustration
PlasmaLEP electrode: design and active-region illustration
Illustration of mechanical separation with energy, by the manufacturer
Illustration of mechanical separation with energy, by the manufacturer

Before adding PlasmaLEP, confirm the generator, working element, electrode and tissue-management equipment together, along with team training.

ELECTRODE SELECTION

Seven electrode designs, selected by task

Plasma EDGE urology electrode range; verify size, reference and compatibility
Plasma EDGE urology electrode range; verify size, reference and compatibility
Thin loop

Thin loop

Thin-wire option for TURBT configuration.

Thick loop

Thick loop

Designed for tissue resection in TURP.

Vaporization electrode

Vaporization electrode

For indicated vaporization and coagulation tasks.

Enucleation electrode

Enucleation electrode

PlasmaLEP design combining mechanical separation with energy.

Needle electrode

Needle electrode

Option for bladder-neck incision and TUIP.

Ball electrode

Ball electrode

For indicated capsule-surface coagulation after resection.

Straight electrode

Straight electrode

Option for access to anterior bladder tumour locations.

Attached cable in the single-use electrode range
Attached cable in the single-use electrode range

Electrode and attached cable: specify the exact reference

Specify tip design, resectoscope size, working-element model and quantity for each reference. Follow the single-use label; do not plan separate reuse of the attached cable.

Lamidey Noury references and illustrations

Checked 10 November 2026. Images illustrate designs and concepts, not the contents of an individual supplied configuration.

Read: Bipolar TURP and saline irrigation →

EQUIPMENT & ACCESSORIES

Equipment & accessories

  • MCB generator and footswitch

    Specify the generator model, required modes, footswitch and connections. Supply configurations may differ within the product family.

  • Working element

    Select for the exact optic and sheath. Compatible working-element options depend on the manufacturer-supported configuration.

  • Optic, sheaths and obturator

    Distinguish 22 and 26 Fr. configurations. The 22 Fr. system lists a 22/19 Fr. double-flow sheath and 2.9 mm / 30° optic. Confirm each component.

  • Electrodes with integrated cable

    Confirm electrode shape, reference, system size and packaging. The displayed range is a set of options, not an automatic list of included items.

คำถามที่พบบ่อย / FAQ

What components form a complete Plasma EDGE system?

Specify the MCB generator, footswitch, connections, compatible working element, optic/sheaths and procedure-specific electrodes. Brochure illustrations do not establish the contents of an individual quotation.

Must the entire existing resectoscope be replaced?

Compatible working elements are available for retaining optics and sheaths in supported configurations. Verify brand, model, size and assembly; compatibility is not universal.

Does the 22 Fr. system use the same components as the 26 Fr. system?

Do not assume interchangeability. The 22 Fr. system comprises a 22/19 Fr. double-flow sheath, dedicated working element and 2.9 mm / 30° optic for the 22 Fr. configuration. Confirm the matching electrodes.

Does saline have to be warmed to 37°C for plasma activation?

Warm saline is not required for operation or plasma ignition. This does not mean all irrigation temperatures are appropriate; follow the applicable IFU and clinical protocol.

How do thin and thick loops differ?

VXRU1 thin loop is intended for TURBT and VXRU2 thick loop for TURP. Confirm geometry, system size and instructions before selection.

Is PlasmaLEP a laser system?

PlasmaLEP is a bipolar enucleation solution within Plasma EDGE, using an electrode designed to combine mechanical separation and energy. It is not a laser attachment and requires technique-specific training.

Can the integrated electrode cable be removed, sterilised and reused?

The single-use electrode range has an integrated cable. Do not plan separate cable reuse; follow the supplied reference’s label and IFU.

Does the system guarantee absence of thermal injury or obturator reflex?

No such guarantee should be inferred. Concentrating the circuit at the electrode does not establish zero complications. Patient assessment, technique and risk management remain necessary.

What should be checked for the MCB generator and adapter?

Training slide 38 describes an MCB unit, footswitch and V11KA98 adapter for the demonstrated setup. Verify current generator and adapter requirements before supply.

What should the team do when an error is displayed?

Follow the unit’s error-specific instructions and involve biomedical engineering or service support when unresolved. Do not force activation or substitute generic advice for the model’s instructions.

Can the 22 Fr. urology setup be treated as the 5 mm gynaecology setup?

No. Urology and gynaecology use different configurations. In the gynaecology workflow, 5 mm refers to the scope/sheath context and 5 Fr. to the instrument channel; these are distinct from 22/26 Fr. urology resectoscopes.

Discuss technical specifications and system configuration

Contact our team to confirm models, specifications, equipment and supply terms.

Talk to our team ↗
โทร / CallLINE @tawanmcweis
REQUEST FOR QUOTATION

Your quotation list

Add equipment, set quantities and send your requirements through our contact form. This list is not an order.